| FEATURES / CONSTRUCTION SYSTEM | PRIME | ENERGY | PASSIVE | ZERO ENERGY | LOG HOUSES |
|---|---|---|---|---|---|
| Energy performance rating (KENAK) | B+ | A | A+ | A+ | B+ |
| External wall thickness | 245 or 180 mm | 315 mm | 365 mm | 365 mm | 205 mm |
| External wall thermal transmittance | 0.22 W/m²K | 0.13 W/m²K | 0.11 W/m²K | 0.11 W/m²K | 0.29 W/m²K |
| Roof thickness | 295 mm | 453 mm | 518 mm | 518 mm | 295 mm |
| Roof thermal transmittance | 0.25 W/m²K | 0.16 W/m²K | 0.13 W/m²K | 0.13 W/m²K | 0.25 W/m²K |
| Windows and balcony doors | PVC, double glazing | PVC, double glazing | PVC, triple glazing | PVC, triple glazing | PVC, double glazing |
| External shutters | ___ | Manual PVC | Electric aluminium | Electric aluminium | ___ |
| Glazing thermal transmittance | 1.0 W/m²K | 1.0 W/m²K | 0.7 W/m²K | 0.7 W/m²K | 1.0 W/m²K |
| Entrance door | Reinforced aluminium/wood | Reinforced aluminium/wood | Airtight PVC | Airtight PVC | Reinforced aluminium/wood |
| Roof tiles | Tegola asphalt shingles | Benders concrete tiles | Benders concrete tiles | Benders concrete tiles | Tegola asphalt shingles |
| Gutters | ___ | Extruded aluminium | Extruded aluminium | Extruded aluminium | ___ |
| Electrical installation | Basic | Complete | Complete | Complete | Basic |
| Plumbing installation | Complete | Complete | Complete | Complete | Complete |
| Heating and cooling system for homes over 80 m² | ___ | Heat pump with fan coils | A+++ 9,000 BTU air conditioner | A+++ 9,000 BTU air conditioner | ___ |
| Heating system for homes under 79 m² | ___ | Electric convectors | A+++ 9,000 BTU air conditioner | A+++ 9,000 BTU air conditioner | ___ |
| Heat recovery ventilation system | ___ | ___ | Included | Included | ___ |
| Domestic hot water heating | ___ | 120-litre solar water heater | 8.00 m² solar collector array with a 500-litre buffer tank | 8.00 m² solar collector array with a 500-litre buffer tank | ___ |
| Energy generation systems | ___ | ___ | ___ | Photovoltaic system | ___ |
| Flooring | Ceramic tiles & laminate | Ceramic tiles & laminate | Ceramic tiles & laminate | Ceramic tiles & laminate | Ceramic tiles & laminate |
| Internal doors | Pressed laminate | Pressed laminate | Pressed laminate | Pressed laminate | Pressed laminate |
| Kitchen cabinets | 4 metres | 6 m for homes ≤99 m² & 10 m for homes >100 m² | 6 m for homes ≤99 m² & 10 m for homes >100 m² | 6 m for homes ≤99 m² & 10 m for homes >100 m² | 4 metres |
| Bedroom wardrobes | 1 unit, 1.20 × 2.65 m / bedroom | 1 unit, 2.00 × 2.65 m for the master bedroom and 1 unit, 1.20 × 2.65 m for each children’s bedroom | 1 unit, 2.00 × 2.65 m for the master bedroom and 1 unit, 1.20 × 2.65 m for each children’s bedroom | 1 unit, 2.00 × 2.65 m for the master bedroom and 1 unit, 1.20 × 2.65 m for each children’s bedroom | 1 unit, 1.20 × 2.65 m / bedroom |
| Staircase | Metal with wooden treads | Glued beechwood | Glued beechwood | Glued beechwood | Glued beechwood |
| Indicative prefabricated home cost* per square metre for a 100 m² home | Contact us to receive your quote | Contact us to receive your quote | Contact us to receive your quote | Contact us to receive your quote | Contact us to receive your quote |
Usefulclarifications
The specifications shown in the comparison tables represent the standard equipment and technical features of each construction system.
The actual energy performance of a home results from the combination of the building envelope with its heating, cooling and domestic hot water systems.
For the PASSIVE system, the final selections are always determined through a detailed PHPP study, ensuring that the required passive building performance standards are achieved.